OxyGuard Atlantic

Product Details

With four relay outputs and 8 set points. There will always be at least one relay output that can be used to give alarm if the oxygen level goes too low or the temperature too high. And since Atlantic measures both parameters and has logical linking you only need to use one relay.

Atlantic also has 8 timers that can be used for a number of purposes. For example, alarm can be delayed so that only a sustained fault results in alarm being given.

Specifications

Specifications for Atlantic Transmitter

  • Construction: ABS enclosure with display, indicators, pushbuttons and alarm buzzer.
  • Dimensions & weight: b x h x d: 213 x 185 x 95 mm, 1.2 kg.
  • Supply & consumption: 230 VAC, 115 VAC +/-10% or 9 to 36VDC. 10 W. Specify when ordering.
  • Operating conditions: -10 to +50°C. Max. 90% humidity non-condensing. Enclosure IP65.
  • Storage conditions: -10 to +60°. Max. 90% humidity non-condensing.
  • Measurement inputs: From probe: mV oxygen signal, resistance temperature signal. Scaleable ranges.
  • Compensation input: 4-20 mA. Scaleable. Max voltage drop 5V at 20 mA.
  • Parameters: mg/l (ppm); % sat; % vol; mbar O2, temperature. Can be scaled and linked.
  • Analogue output: 4-20 mA. Max. load 820 ohm (total). User selectable range & parameter. Fully galvanically isolated from all inputs.
  • Display: Graphical LCD with backlight. Max 4 figures, 2 decimals, 13 mm height.
  • Conversion accuracy: To display and analogue output < +/- 0.1%. Non-linearity and repeatability typically < +/- 0.1% of actual value.
  • Relay outputs: 4, with potential free changeover (SPDT) contacts. Selectable mode (direct or inverted), and linking to parameter or logical argument. Max load 200VA or 1A AC, recommended max 24 VAC (abs. max 250 VAC). 2A at 24 VDC.
  • Logical functions: Direct, inverted, multiply. With "and" and "not and" linking.
  • Alarms: 8, variable hysteresis about set point. Selectable parameter, values & linking.
  • Timers: 8, from 1 second to 999999 seconds (11 days). Selectable period, duty cycle and offset. Can activate or be activated by alarm. Can freeze the output. Can activate relays. Can be reset from front panel.

Specifications for OxyGuard Probe

  • Measurement principle: Oxygen: Galvanic oxygen partial pressure cell, self polarizing, self temperature compensating. Temperature: Precision NTC
  • Dimensions: Diameter = 58 mm, length = 59 mm.
  • Weight: Probe alone 0.2 kg. Probe with 7m cable 0.5 kg.
  • Connections: Cable, 4 lead, standard cable length = 7 m.
  • Measurement range: 0 to 20 mg/l (ppm)/ 0 to 200 % sat, higher on request. Temp. from -5°C.
  • Accuracy: Depends on calibration and conditions. Typical better than +/-1% of value.
  • Output stability: In air at constant temperature stable to within +/- 1% over 1 year.
  • Accuracy, temperature: +/- 0,3°C.
  • Operating conditions: 0 to 40°C, pressure to 2 bar. Higher on request.
  • Storage temperature: -5 to +60°C.

Ordering Information

  • B071A: OxyGuard Atlantic with probe for Aquaculture. Output 4-20 mA = 0-20 mg/l. Relay 1 active on low mg/l. Relay 2 activate on low % sat. Relay 3 de-activate on low % sat (or power failure.)
  • B072A: OxyGuard Atlantic with probe for Aquaculture. Version with analogue compensation input Output 4-20 mA = 0-20 mg/l. Relay 1 active on low mg/l. Relay 2 activate on low % sat. Relay 3 de-activate on low % sat (or power failure.)
  • Please specify operating voltage - 230 VAC, 115 VAC or 24 VDC.
  • STXWOHR: Configuration to customer specification per hour.
  • I01FS: OxyGuard Fix-Mount Salinity Meter.
  • D10CAFADD: Anti-Fouling Cap fitted to probe.