OxyGuard Temperature Probes

Specifications

Sensor

Construction: Sensor tip 9mm dia. x 32 mm. Body 21.5 mm dia. Total length with cable gland 117 mm. Also available with ½" pipe thread. Other body shapes available on request.

Cable length: Standard cable 5 m 2-wire 0.75 mm2 PUR. Other lengths available on request.

Operating temperature: Standard range: -5°C to +45°C.

Accuracy: +/- 0.2 deg. C

Standard Accessories: Junction box with terminals and cable glands.

Probe with 4-20 mA Transmitter

Construction: Sensor tip 9mm dia. x 32 mm. Body 21.5 mm dia. Total length with cable gland 138 mm. Also available with ½" pipe thread. Other body shapes available on request.

Cable length: Standard cable 5 m 2-wire 0.75 mm2 PUR. Other lengths available on request.

Operating temperature: Standard range: -5°C to +45°C.

Calibration: Factory calibrated; 4-20 mA = -5°C to +45°C. Other values on request.

Accuracy: +/- 0.2 deg. C

Warm-up time: 1 millisecond.

Supply: 14 volt (50 ohm loop resistance) to 36 VDC (abs. max.) (1200 ohm resistance).

Standard Accessories: Junction box with terminals and cable glands.

Ordering Information

D061: Standard temperature probe.

D062: Temperature probe with built-in transmitter

D062TH: as D062 but with thread mount.

D063: Temperature probe with PT100 sensor.